CWOP temperature truncation?

 
Post new topic   Reply to topic    wviewweather.com Forum Index -> CWOP
View previous topic :: View next topic  
Author Message
Guest






PostPosted: Fri Dec 02, 2005 9:20 am    Post subject: CWOP temperature truncation? Reply with quote

Not 100% sure if this is wview or the CWOP system but it appears that fractional temperature values are simply being truncated rather than rounded when input to CWOP.

For example, if my system is reporting that the temperature is 22.8F, CWOP will record it as being 22F, not 23F as is shown on my Vantage console. Meanwhile wview will upload 22.8F to Weather Underground and record 22.8F in my Postgres database.

greg
Back to top
mteel



Joined: 30 Jun 2005
Posts: 435
Location: Collinsville, TX

PostPosted: Fri Dec 02, 2005 10:06 am    Post subject: Reply with quote

CWOP wants temperatures in whole numbers, but I was truncating instead of rounding. I have just changed that. Also, I was interpreting negative temperatures from the wviewd daemon as "no value" instead of negative temperatures. I have fixed that as well.

Thanks for pointing this out, it will be in the 1.8.6 release this weekend.
Back to top
View user's profile Send private message Send e-mail Visit poster's website
Display posts from previous:   
Post new topic   Reply to topic    wviewweather.com Forum Index -> CWOP All times are GMT - 6 Hours
Page 1 of 1

 
Jump to:  
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum


Powered by phpBB © 2001, 2005 phpBB Group